DURASTRIP
ARS-40
|
|
Aqueous Dry Film
Resist Stripper
|
Description:
|
|
DURASTRIP ARS-40 is
an alkaline stripper concentrate designed to strip aqueous dry film
photo resists. It can be used for tank stripping at ambient temperatures.
DURASTRIP ARS-40 has a low odor level, exhibits minimal foaming,
and leaves a bright, clean surface. It was designed for use with
DYNACHEM GA, HG, and FL, ETERTEC 5600, 5700, and 7200; and DuPONT
9000, 9400, 4600, and PrintMaster films.
|
Benefits:
|
- Minimal odor.
- Fast stripping
- High load capacity
- Good film breakup
at room temperature.
|
Properties:
|
|
Form:
Clear, water-white liquid
pH, concentrate: 14
pH, @ 15% by volume: 12.5 to 12.8
Specific gravity: 1.018
Weight/Gallon 8.4947
Solubility, water: Infinite
Flash point: >200°
Odor: Mild,
characteristic
|
Applications:
|
|
DURASTRIP ARS-40 was
designed to strip aqueous resists and to leave a bright, clean,
uniform surface ideal for optical inspection. ARS-40 is compatible
with all feed and bleed systems.
|
Directions For Use:
|
|
Bath Make-up: 10
to 20% by volume with water
Temperature: 125°F
± 5° F
Time: 30
seconds to 1 1/2 minutes depending on temperature, resist type,
and exposure level.
Operation: Static
tank or spray
|
Equipment:
|
|
TANKS: polypropylene,
PVC, PVDC, polypropylene
HEATERS: Titanium, Stainless
Steel, Quartz, Teflon Coated, quartz
SPRAY MODULES: PVC,
polypropylene, 316 s/s and titanium
RACKS: 316 Stainless
Steel
|
Maintenance:
|
|
There are three (3)
methods of maintaining DURASTRIP ARS-10: (1) conveyor-breakpoint,
(2) pH control, or (3) by titration to maintain % by volume. A conveyorized
spray system with an efficient mans of resist particle removal will
generally have longer stripper life than one that does not. . The
bath will not function below a pH of 9.0
|
Control:
|
|
Analytical procedure
for percent by volume of stripper:
- REAGENTS
- Hydrochloric
acid, 1.0 Normal
- Phenolphthalien
indicator solution.
- APPARATUS
- Flask, 250 ml
- One 10 ml pipet
- One 50 ml buret
- PROCEDURE
- Pipet 10 ml sample
from bath into 250 ml flask
- Add 100 ml distilled
water.
- Add 3 - 4 drops
of indicator
- Titrate from
a reddish pink to a very pale pink end point.
- CALCULATIONS
- ml of titrate
X Normality X 17 / 10 = percent of volume
|
Safety:
|
|
DURASTRIP ARS-40 is
a strong alkaline solution and should be used in accordance with
proper and appropriate safety practices. Goggles, face shield, apron,
gloves, and any other appropriate safety equipment should be worn
when mixing or otherwise handling this material. Proper exhaust
to keep fumes out of the work area is a must.
In case of skin contact
flush with copious quantities of fresh, cool water. In case of eye
contact, flush immediately with cool fresh water for 15 minutes
by the clock minimum and consult a physician immediately. In case
of accidental ingestion, consult a physician immediately.
|
Disposal:
|
- Lower the pH of the
spent solution with sulfuric acid to pH of 1.5 to 2.0 to coagulate
any dissolved resist.
- Separate by decantation
or filtration and dispose of the solid, according to local, state,
and federal regulations.
- Raise the pH with
sodium hydroxide to 8 to 9.
- Treat with sodium
sulfide or thiocarbamate and filter for removal of metals such
as copper, tin and lead. NOTE: If solution is allowed to become
acidic, poisonous sulfide gas will form. Do not let pH drop below
7.
- Check with local,
state, and federal agencies for disposal of remaining liquid material.
|
Storage:
|
|
Keep containers sealed.
Keep partial containers closed at all times. Store product away
from sources of direct heat. Keep away from acidic materials and
strong oxidizing agents.
|
Shelf Life:
|
|
DURASTRIP ARS-40 is
guaranteed for (1) year from date of receipt in unopened containers.
|
Containers:
|
|
Five gallon pails and
55 gallon nonreturnable plastic drums.
|
Classification:
|
|
National Motor Freight
Classification NO. 429200, Sub I
DOT Hazardous Material Description: Ehtanolamine Solution
Hazardous Class: Class 8
I.D Number: UN 2491, packing group III
Label Required: Corrosive
|
|
The information contained
herein is based on our experience and is believed to be reliable.
However, since methods and conditions of use of our products as
described are beyond our control, both the product and instructions
for its use are offered without warranty, expressed or implied.
No information on this data should be construed as a recommendation
by DURATECH INDUSTRIES, INC., to use any product in contravention
of any patent right.
|